Datoptic RM12-S6.TB - Rackmount Manual do Utilizador Página 63

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 90
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 62
APPENDIX
172
C-3-3 Using In-band PCIe + SNMP extension agent Instal-
lation
By using the IP address assigned to the operating- RAID control-
ler using Areca SNMP extension agent through PCIe host bus
interface.
a). Set only “Community” eld and keep space (or zero) on all
“SNMP Tarp IP Address“ options on the rmware-embedded SNMP
conguration function. There is no function to set other elds on
“SNMP System Conguration”.
The SNMP “Community” and “SNMP Tarp IP Address” can setup
by using browser-based manager or CLI SNMP conguration. To
launch the browser-based RAID controller SNMP function, click
on the “System Controls” link. The “System Controls” menu will
show available items. Select the “SNMP Conguration” item. The
following “SNMP System Conguration” screen is launched by
browser-based manager.
About community, Community name acts as a password to screen
accesses to the SNMP agent of a particular network device. Type
in the community names of the SNMP agent. Before access is
granted to a request station, this station must incorporate a valid
community name into its request; otherwise, the SNMP agent will
deny access to the system.
Most network devices use “public” as default of their community
names. This value is case-sensitive.
b). Mark the check box on the ‘SNMP Through PCI Inband” setting
Vista de página 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 89 90

Comentários a estes Manuais

Sem comentários